JI Nian, MA Chaochen. Design and measurement error estimation of a shielded total temperature probe[J]. Journal of Aerospace Power, 2023, 38(7):1749-1761 doi: 10.13224/j.cnki.jasp.20210620
Citation: JI Nian, MA Chaochen. Design and measurement error estimation of a shielded total temperature probe[J]. Journal of Aerospace Power, 2023, 38(7):1749-1761 doi: 10.13224/j.cnki.jasp.20210620

Design and measurement error estimation of a shielded total temperature probe

doi: 10.13224/j.cnki.jasp.20210620
  • Received Date: 2021-10-31
    Available Online: 2023-04-25
  • Ignoring the radiation error, the velocity error and heat conduction error of a shielded total temperature probe under different working conditions were predicted by using the conjugate heat transfer numerical simulation method. Results showed that the thermal conductivity error was kept at a small value in the range of Mach number from 0.2 to 0.6; more than 90% of the total error was contributed by velocity error; the maximum measurement error was 1.13 K, which was 331.62%, 119.4%, 61.6% and 59.5% lower than the common structure A, B, C and D, respectively; velocity error and conduction error affected each other, and there was an optimal solution to minimize the total error. It was applicable to the total temperature measurement of isothermal incoming flow and high-speed non-isothermal incoming flow with Mach number greater than 0.5. Finally, the influence of thermocouple junction position on measurement accuracy was discussed. When the junction was kept away from the support from the design point, the measurement error followed the change law of first increasing and then decreasing.

     

  • loading
  • [1]
    ARENZ M C, WEIGEL B, HABERMANN J, et al. Development and application of a fast-response total temperature probe for turbomachinery[R]. Seoul, Korea: ASME Turbo Expo: Turbomachinery Technical Conference and Exposition, 2016.
    [2]
    KIDD S R,BARTON J S,MEREDITH P,et al. A fiber optic probe for gas total temperature measurement in turbomachinery[J]. Journal of Turbomachinery,1995,117(4): 635-641. doi: 10.1115/1.2836582
    [3]
    WANG G, BONILLA C, KALITAN D. Gas temperature field measurement using thin-filament pyrometry[C]// Proceedings of the ASME Turbo Expo: Turbine Technical Conference and Exposition. Düsseldorf, Germany: ASME, 2014: 1-11.
    [4]
    杨伟平,张伟昊,邹正平,等. 屏蔽式总温热电偶的稳态误差分析及改型设计[J]. 航空动力学报,2018,33(11): 2784-2795. doi: 10.13224/j.cnki.jasp.2018.11.025

    YANG Weiping,ZHANG Weihao,ZOU Zhengping,et al. Steady state error estimation and modification of a shielded thermocouple[J]. Journal of Aerospace Power,2018,33(11): 2784-2795. (in Chinese) doi: 10.13224/j.cnki.jasp.2018.11.025
    [5]
    杨灿,吴伟力,熊义彬,等. 航空发动机燃烧室出口高温热电偶校准技术[J]. 航空动力学报,2016,31(4): 769-774. doi: 10.13224/j.cnki.jasp.2016.04.001

    YANG Can,WU Weili,XIONG Yibin,et al. Calibration technology of high-temperature thermocouple for combustor exit of an aero-engine[J]. Journal of Aerospace Power,2016,31(4): 769-774. (in Chinese) doi: 10.13224/j.cnki.jasp.2016.04.001
    [6]
    VILLAFAÑE L,PANIAGUA G. Aero-thermal analysis of shielded fine wire thermocouple probes[J]. International Journal of Thermal Sciences,2013,65: 214-223. doi: 10.1016/j.ijthermalsci.2012.10.025
    [7]
    ZOU Zhengping,YANG Weiping,ZHANG Weihao,et al. Numerical modeling of steady state errors for shielded thermocouples based on conjugate heat transfer analysis[J]. International Journal of Heat and Mass Transfer,2018,119: 624-639. doi: 10.1016/j.ijheatmasstransfer.2017.11.034
    [8]
    HARADA T,WATANABE H,SUZUKI Y,et al. A numerical investigation of evaporation characteristics of a fuel droplet suspended from a thermocouple[J]. International Journal of Heat and Mass Transfer,2011,54(1/2/3): 649-655. doi: 10.1016/j.ijheatmasstransfer.2010.08.021
    [9]
    SKOVORODKO P A,TERESHCHENKO A G,KNYAZKOV D A,et al. Experimental and numerical study of thermocouple-induced perturbations of the methane flame structure[J]. Combustion and Flame,2012,159(3): 1009-1015. doi: 10.1016/j.combustflame.2011.10.010
    [10]
    BLAY V,BOBADILLA L F. Numerical study of the accuracy of temperature measurement by thermocouples in small-scale reactors[J]. Chemical Engineering Research and Design,2018,131: 545-556. doi: 10.1016/j.cherd.2017.06.003
    [11]
    REARDON J, SCHETZ J A, LOWE K T. Computational modeling of total temperature probes[J]. Journal of Thermophysics and Heat Transfer, 2017, 31(3): 609-620.
    [12]
    CHEN Xue,XIA Xinlin,SUN Chuang,et al. Numerical analysis on the transient measurement of gas temperature in porous material using thermocouples at high temperatures[J]. International Journal of Heat and Mass Transfer,2015,91: 1060-1068. doi: 10.1016/j.ijheatmasstransfer.2015.08.055
    [13]
    ZEISBERGER A. Total temperature probes for turbine and combustor applications[C]// Proceedings of 18th International Society of Air-breathing Engines (ISABE) Conference. Beijing: AIAA, 2007: 1-8.
    [14]
    MOFFAT R J. Gas temperature measurement[J]. Temperature: Its Measurement and Control in Science and Industry, 1962, 3: 553-571.
    [15]
    PANIAGUA G, DENOS R, OROPESA M. Thermocouple probes for accurate temperature measurements in short duration facilities[C]// Proceedings of the ASME Turbo Expo: Power for Land, Sea, and Air. Amsterdam, Netherlands: ASME, 2002: 209-217.
    [16]
    KULKARNI K S,MADANAN U,GOLDSTEIN R J. Effect of freestream turbulence on recovery factor of a thermocouple probe and its consequences[J]. International Journal of Heat and Mass Transfer,2020,152: 119498.1-119498.5.
    [17]
    VINCENT T G,ROLFE E N,LOWE K T,et al. Aerodynamic analysis of total temperature probe thermal performance using conjugate heat transfer[J]. Journal of Thermophysics and Heat Transfer,2019,33(3): 830-843. doi: 10.2514/1.T5635
    [18]
    杨世铭, 陶文铨. 传热学[M]. 4版. 北京: 高等教育出版社, 2006
    [19]
    WHITAKER S. Forced convection heat transfer correlations for flow in pipes, past flat plates, single cylinders, single spheres, and for flow in packed beds and tube bundles[J]. AIChE Journal,1972,18(2): 361-371. doi: 10.1002/aic.690180219
    [20]
    GLAWE G E, SIMMONS F S, STICKNEY T M. Radiation and recovery corrections and time constants of several chromel-alumel thermocouple probes in high-temperature, high-velocity gas streams[R]. NACA Technical Note 3766, 1956.
    [21]
    STICKNEY T M. Recovery and time-response characteristics of six thermocouple probes in subsonic and supersonic flow[R]. NACA Technical Note 3455, 1955.
    [22]
    刘嗣鉷,赵觉良. 总温热电偶的最佳设计[J]. 工程热物理学报,1981,2(2): 197-199.

    LIU Sihong,ZHAO Jueliang. An optimum design procedure of total temperature thermocouple[J]. Journal of Engineering Thermophysics,1981,2(2): 197-199. (in Chinese)
    [23]
    吴颖, 田金光, 赵宇. 某重型燃机用排气总温热电偶的设计与研究[C]//航空试验测试技术学术交流会论文集. 西安: 中国学术期刊电子出版社, 2011: 312-317.
    [24]
    秦存民, 廖理, 杨永军, 等. 横向屏蔽式热电偶温度传感器屏蔽罩的优化设计研究[C]//广西 桂林: 第5届全国温度测量与控制技术学术会议论文集, 2007: 375-379.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (649) PDF downloads(178) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return