Volume 7 Issue 3
Jul.  1992
Turn off MathJax
Article Contents
Peng Jian, Jiang Haokang. A PLATINUM-FILM RESISTANCE TEMPERATURE PROBE FOR UNSTEADY FLOW MEASUREMENTS[J]. Journal of Aerospace Power, 1992, 7(3): 248-252,292.
Citation: Peng Jian, Jiang Haokang. A PLATINUM-FILM RESISTANCE TEMPERATURE PROBE FOR UNSTEADY FLOW MEASUREMENTS[J]. Journal of Aerospace Power, 1992, 7(3): 248-252,292.

A PLATINUM-FILM RESISTANCE TEMPERATURE PROBE FOR UNSTEADY FLOW MEASUREMENTS

  • Publish Date: 1992-07-28
  • A platinum film resistance temperature probe has been designed.Steady tests show that the linearity error of the probe is less than 0 5%.The thermal response of the probe has been checked by both shock tube and high frequency hot jet.It is shown that the frequency response of 6 kHz can be expected.According to heat transfer analysis,the thermal properties and the size of the base bar are the main factors of the effect on thermal response of the probe.The probe has been successfully used for measuring rotating stall signals of a single stage transonic compressor.The study shows that the film resistance temperature probe features high frequency response,fine linearity,high sensitivity and ease to use,so it has a bright prospect in application to unsteady flow measurements.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (1686) PDF downloads(445) Cited by()