ZHU Guo dong, LI Pei jun, SHAN Peng. Investigation on the Maximum Single Stage Loading Level of the Super- or Tran-Sonic Axial Flow Fans and Compressors[J]. Journal of Aerospace Power, 2002, 17(5): 538-541.
Citation: ZHU Guo dong, LI Pei jun, SHAN Peng. Investigation on the Maximum Single Stage Loading Level of the Super- or Tran-Sonic Axial Flow Fans and Compressors[J]. Journal of Aerospace Power, 2002, 17(5): 538-541.

Investigation on the Maximum Single Stage Loading Level of the Super- or Tran-Sonic Axial Flow Fans and Compressors

  • Received Date: 2001-11-16
  • Rev Recd Date: 2002-01-17
  • Publish Date: 2002-12-28
  • The quest for higher stage pressure ratio has been promoted by engine researchers.But in the multi stage fan and compressors,the rise in total and static pressures of a single stage axial flow compressor is constrained by many factors.The maximum stage loading level has a limitation.Using a simplified stage model,this paper investigates this level of a super or tran sonic single stage axial flow compressor under the conditions of the widest rotor stator matching and the stage matching.The paper concludes that the stage pressure ratio must be less than 37 when considering only the theoretical loading mechanism.Meanwhile it gives several graphs to exhibit the influencing strength of each constraint.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (1586) PDF downloads(456) Cited by()