XU Quan-hong, LIN Yu-zhen, LIU Gao-en. Rig Test of Impingement/Effusion Double Wall Cooling Methods for the Main Combustor[J]. Journal of Aerospace Power, 2005, 20(2): 197-201.
Citation: XU Quan-hong, LIN Yu-zhen, LIU Gao-en. Rig Test of Impingement/Effusion Double Wall Cooling Methods for the Main Combustor[J]. Journal of Aerospace Power, 2005, 20(2): 197-201.

Rig Test of Impingement/Effusion Double Wall Cooling Methods for the Main Combustor

  • Received Date: 2004-03-04
  • Rev Recd Date: 2004-06-03
  • Publish Date: 2005-04-28
  • For the investigation, a combustor sector with one burner head was used.Three different test pieces with impingement/effusion double wall cooling were selected for testing under high-temperature and high-pressure working conditions,which were equivalent to that of engines with a thrust/weight ratio of 10.The liner temperatures were measured using thermocouples.The test result shows that the amount of cooling airflow of double-layer wall combustor is 20% of the overall airflow,and the overall cooling effectiveness is in the range of 0.85 to 0.96.The wall temperatures of all test pieces are lower than 1 150 K.

     