This paper presented an experimental investigation the effects of the trailing edge cooling on the aerodynamic performance. The experiments were conducted on the low-speed linear cascade tunnel at Northwestern Polytechnical University. The external aerodynamic characteristics in the 40 percent chord downstream of exit plane were measured using five-hole probe with the different ejection rates. The results showed that the total pressure loss coefficient at the middle spanwise plane increased at first and then it has a decreasing tendency with the increase of ejection ratio. The trailing edge cooling would influence the structure of the turbine cascade outlet flow field. When the ejection rate was 3%,the loss area near the blade endwall would become stronger,but it would become weaker with the 6% ejection ratio. On the whole,the trailing edge cooling had more influence on the profile loss than on the secondary loss.