Volume 25 Issue 9
Sep.  2010
Turn off MathJax
Article Contents
ZHANG Xing-juan, LI Feng, YANG Chun-xin. Calculation method for matching enthalpy parameter of three-wheel bootstrap high-pressure water-separated system[J]. Journal of Aerospace Power, 2010, 25(9): 1938-1941.
Citation: ZHANG Xing-juan, LI Feng, YANG Chun-xin. Calculation method for matching enthalpy parameter of three-wheel bootstrap high-pressure water-separated system[J]. Journal of Aerospace Power, 2010, 25(9): 1938-1941.

Calculation method for matching enthalpy parameter of three-wheel bootstrap high-pressure water-separated system

  • Received Date: 2009-07-22
  • Rev Recd Date: 2010-01-04
  • Publish Date: 2010-09-28
  • A calculation model for matching the enthalpy parameters of three-wheel bootstrap cooling system was introduced according to the shortcomings of traditional method for matching thermal parameters.The model could simplify the wet cooling point matching process.And the thermal parameters of each system's status point was calculated by the model.The results show that,with the use of enthalpy instead of temperature as the state parameter for system matching,it's viable to simplify the calculation process.An optimal water equivalent ratio is found by system performance analysis;as the three-wheel power ratio increases,the compressor pressure ratio and turbine expansion ratio decrease.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (1619) PDF downloads(432) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return