Volume 22 Issue 9
Sep.  2007
Turn off MathJax
Article Contents
LUO Ming-dong, JI Hong-hu, HUANG Wei, CAI Xu, GAO Chao. Research on measurement method of mid-IR spectral radiant intensity of exhaust system with FTIR spectrometer[J]. Journal of Aerospace Power, 2007, 22(9): 1423-1429.
Citation: LUO Ming-dong, JI Hong-hu, HUANG Wei, CAI Xu, GAO Chao. Research on measurement method of mid-IR spectral radiant intensity of exhaust system with FTIR spectrometer[J]. Journal of Aerospace Power, 2007, 22(9): 1423-1429.

Research on measurement method of mid-IR spectral radiant intensity of exhaust system with FTIR spectrometer

  • Received Date: 2006-09-07
  • Rev Recd Date: 2006-12-04
  • Publish Date: 2007-09-28
  • The reasons of error occurred in measuring Mid-IR spectral radiant intensity of exhaust system with Fourier transform infrared(FTIR) spectrometer was discussed through theoretical analysis and experimental research.A simple and efficient measurement method was also planned to measure the spectral radiant intensity of a blackbody and a hot plume.The results show that Mid-IR spectral radiant intensity of exhaust system could be measured effectively by this method,thus offering a high value of engineering practicability.

     

  • loading
  • [1]
    Varney G E.Infrared signature measurement techini ques and simulation methods for aircraft survivability[R].AIAA-79-1186.
    [2]
    Kroutil R T,Combs R J,Knapp R B.Radiometric linearity in passive FTIR spectrometry[J].SPIE,1999,3856:34-43.
    [3]
    George M R,Bill P.Uncertainties in FTIR data due to a nonlinear response[J].SPIE,1998,3534:176-186.
    [4]
    张天舒,刘文清,高闽光,等.傅里叶变换红外光谱仪复数光谱误差分析及辐射定标方法研究[J].光谱学与光谱分析,2006,26(3):430-433.ZHANG Tianshu,LIU Wenqing,GAO Minguang,et al.Error analysis and calibration method of complex spectrum of fourier transform infrared spectrometer[J].Spectroscopy and Spectral Analysis,2006,26(3):430-433.
    [5]
    朱军,刘文清,陆亦怀,等.基于FTIR光谱辐射测量分析空气透过率[J].光学技术,2005,31(4):627-629.ZHU Jun,LIU Wenqing,LU Yihuai,et al.Analysis of atmospheric transmittance based on FTIR spectra measureme nts[J].Optical Technique,2005,31(4):627-629.
    [6]
    张黎明,张琳,李燕,等.被动式遥感FTIR测量时的仪器响应函数校正[J].光谱学与光谱分析,2006,26(1):45-46.ZHANG Liming,ZHANG Lin,LI Yan,et al.The calibration of instrument response function during passive FTIR measure-ment[J].Spectroscopy and Spectral Analysis,2006,26(1):45-46.
    [7]
    吴航行,王模昌.傅立叶变换光谱仪信号调制度下降的分析[J].红外与毫米波学报,2004,23(5):337-344.WU Hangxing,WANG Mochang.Analysision the decrease of signal modulation in fourir transform spectrometer[J].J.Infrared Millim Waves,2004,23 (5):337-344.
    [8]
    ABB Bomen Inc.MR series FT-spectro radiometer design overview and theory (Version 3.0)[M].Quebec,Canada:ABB Bomen Inc,1999.
    [9]
    ABB Bomen Inc.MR series FT-spectro radiometer research acquire radiometric software manual (Version 3.0)[M].Quebec,Canada:ABB Bomen Inc,1999.
    [10]
    徐南荣,卞恩华.红外辐射与制导[M].北京:国防工业出版社,1995.
  • 加载中