Measured overall effusion cooling effectiveness over a wide blowing ratio range using infrared imaging
Measured overall effusion cooling effectiveness over a wide blowing ratio range using infrared imaging
-
摘要: Experimental investigations were performed on the overall cooling effectiveness η of a flat effusion wall over a wide range of blowing ratio(M=0.47~5.27).The effusion wall had a staggered multi-hole pattern typical of gas turbine combustor application,with a ratio of hole pitch to row spacing P/S=1∶2,a porosity PS/d2=72,and an inclination angle α=30°.The current paper documented distribution of the overall cooling effectiveness on the wall surface,based on infrared imaging of the 2-D surface tem...Abstract: Experimental investigations were performed on the overall cooling effectiveness η of a flat effusion wall over a wide range of blowing ratio(M=0.47~5.27).The effusion wall had a staggered multi-hole pattern typical of gas turbine combustor application,with a ratio of hole pitch to row spacing P/S=1∶2,a porosity PS/d2=72,and an inclination angle α=30°.The current paper documented distribution of the overall cooling effectiveness on the wall surface,based on infrared imaging of the 2-D surface tem...
-
Key words:
- gas turbine /
- effusion cooling /
- overall cooling effectiveness /
- blowing ratio /
- infrared imaging
-