基于翅片板结构的烟气对流冷凝传热性能

顾黎昊 凌祥 彭浩

顾黎昊, 凌祥, 彭浩. 基于翅片板结构的烟气对流冷凝传热性能[J]. 航空动力学报, 2012, 27(12): 2692-2698.
引用本文: 顾黎昊, 凌祥, 彭浩. 基于翅片板结构的烟气对流冷凝传热性能[J]. 航空动力学报, 2012, 27(12): 2692-2698.
GU Li-hao, LING Xiang, PENG Hao. Experiment on forced convection-condensation heat transfer characteristics based on finned plate configuration[J]. Journal of Aerospace Power, 2012, 27(12): 2692-2698.
Citation: GU Li-hao, LING Xiang, PENG Hao. Experiment on forced convection-condensation heat transfer characteristics based on finned plate configuration[J]. Journal of Aerospace Power, 2012, 27(12): 2692-2698.

基于翅片板结构的烟气对流冷凝传热性能

基金项目: 江苏省科技支撑计划(BE2008005); 新世纪优秀人才支持计划(NCET-07-0434)

Experiment on forced convection-condensation heat transfer characteristics based on finned plate configuration

  • 摘要: 在冷凝实验台上对一种用于冷凝式烟气余热回收的翅片板换热器进行实验,研究了该结构的传热和流动性能,分析了烟气温度、流速等对冷凝的影响,得到了Nu-Ref-Re曲线,并对该换热结构在干空气风洞实验台上测试的结果进行了比对.结果表明:由于大量不凝性气体的影响(质量分数为92%),冷凝传热对整体传热性能的强化并不明显,伴随有冷凝的烟气表面传热系数约为相同工况下无凝结表面传热系数的1.1~1.2倍.得到了无量纲数冷凝传热准则关联式,可以为冷凝式翅片板换热器的设计提供参考.

     

  • [1] 曹彦斌,艾效逸,郭全,等.伴随有水蒸气凝结的烟气对流换热的实验研究[J].工程热物理学报,2000,21(6):729-733.CAO Yanbin,AI Xiaoyi,GUO Quan,et al.Investigation on forced convective heat transfer with steam condensation of flue by experiment[J].Journal of Engineering Thermophysics,2000,21(6):729-733.(in Chinese)
    [2] Stehlík P.Conventional versus specific types of heat exchangers in the case of polluted flue gas as the process fluid:a review[J].Applied Thermal Engineering,2011,31(1):1-13.
    [3] Kukulka D J,Devgun M.Fluid temperature and velocity effect on fouling[J].Applied Thermal Engineering,2007,27(16):2732-2744.
    [4] Rohsenow W M,Hartnett J P,Ganic E N.Handbook of heat transfer applications[M].New York:McGraw Hill,1985.
    [5] Smith E M.Thermal design of heat exchangers[M].New York:John Wiley & Sons,1997.
    [6] SHI Xiaojun,CHE Defu,Agnew B,et al.An investigation of the performance of compact heat exchanger for latent heat recovery from exhaust flue gases[J].Int.J.Heat Mass Tran.,2011,54(1):606-615.
    [7] CHEN Qun,Karen F,LI Hanning,et al.Condensing boiler applications in the process industry[J].Applied Energy,2012,89(1):30-36.
    [8] Jeong K,Kessen M J,Bilirgen H,et al.Analytical modeling of water condensation in condensing heat exchanger[J].Int.J Heat Mass Tran.,2011,53(11):2361-2368.
    [9] 周兴东,马学虎,张宇,等.含有不凝气体的蒸汽滴状冷凝传热实验研究[J].工程热物理学报,2004,25(6):1001-1003.ZHOU Xingdong,MA Xuehu,ZHANG Yu,et al.Experimental investigation of dropwise condensation in the presence of non-condensable gas[J].Journal of Engineering Thermophysics,2004,25(6):1001-1003.(in Chinese)
    [10] 周兴东,马学虎,兰忠,等.滴状冷凝强化含不凝气的蒸汽冷凝传热机制[J].化工学报,2007,58(7):1619-1625.ZHOU Xingdong,MA Xuehu,LAN Zhong,et al.Mechanism of dropwise condensation heat transfer enhancement in presence of non-condensable gas[J].Journal of Chemical Industry and Engineering,2007,58(7):1619-1625.(in Chinese)
    [11] Slegers L,Seban R A.Laminar film condensation of steam containing small concentrations of air [J].Int.J.Heat Mass Tran.,1970,13(12):1941-1947.
    [12] Jia L,Peng X F,Sun J D,et al.An experimental study on vapor condensation of wet flue gas in a plastic heat exchanger[J].Heat Transfer-Asian Research,2001,30(7):571-580.
    [13] Masahiro O,Kazuhiko I,Kiyoyuki Y,et al.Condensation heat transfer on tubes in actual flue gas[J].Heat Transfer-Asian Research,2003,32(2):153-166.
    [14] MA Xuehu,ZHOU Xingdong,LAN Zhong,et al.Condensation heat transfer enhancement in the presence of non-condensable gas using the interfacial effect of dropwise condensation[J].Int.J Heat Mass Tran.,2008,51(7):1728-1737.
    [15] Foumeny E A,Ma J.Heat exchangers engineering[M].New York:Ellis Horwood,1993.
  • 加载中
计量
  • 文章访问数:  1709
  • HTML浏览量:  85
  • PDF量:  1418
  • 被引次数: 0
出版历程
  • 收稿日期:  2011-12-08
  • 刊出日期:  2012-12-28

目录

    /